About the Digital Inputs and Outputs 
All general purpose inputs and outputs are optically isolated. They operate in the 12–24 VDC range, and 
can be wired to be either sinking into or sourcing from the Geo Brick Drive.  
 
Inputs 
The inputs use the 
 photocoupler.  
For sourcing inputs, connect the input common pin(s) to the 12–24V line of the power supply. The input 
devices  are  then  connected  to  the  common  ground  line  of  the  power  supply  at  one  end,  and  individual 
input pins at the other. 
For sinking inputs, connect the input common pin(s) to the common ground line of the power supply. The 
input devices are then connected to the 12–24V line of the power supply at one end, and individual input 
pins at the other. 
 
 
Note 
The  inputs  can  be  wired  either  sourcing  or  sinking  in  sets  of  eight, 
with each set possessing its own common.   
 
Outputs 
The  outputs,  in  the  older  models  of  the  Geo  Brick  Drive,  use  the 
  photocoupler.  They 
are rated to a maximum current of 500 mA, and are overload protected. 
 
The outputs, in the newer models of the Geo Brick Drive (control board 603793-10A and later), use the 
  photocoupler.  They  are  protected  with  a 
;  an  enhancement  mode 
MOSFET - diode incorporated. The protection involves over-voltage, over-current, I2T and short circuit. 
 
For  sourcing  outputs,  connect  the  common  collector  (pin  #29)  to  the  12–24V  line  of  the  power  supply. 
The  output devices are then connected to the common ground  line  of the power supply at one  end, and 
individual sourcing output pins at the other. 
For  sinking  outputs,  connect  the  common  emitter  (pin  #11)  to  the  common  ground  line  of  the  power 
supply.  The  output  devices  are  then  connected  to  the  12–24V  line  of  the  power  supply  at  one  end,  and 
individual sinking output pins at the other. 
 
 
Note 
Do  not  mix  topologies  for  outputs.  They  are  all  either  sinking  or 
sourcing.  If the common emitter is used, the common collector should 
not be connected and vice versa. 
 
 
Note 
Newer  models  of the Geo  Brick Drive  were introduced in October of 
2012.  They  can  be  recognized  by  the  4-pin  terminal  block  logic  and 