6.4 DC CHARACTERISTICS 
 
6.4.1  on-hook AC impedance  
 
Required result: 
 
 
 
 
 
   f < 200  Hz : 
More than 
25 kohm  
 
 
 
697 < f < 1,633  Hz : 
More than 
80 kohm 
   f > 3,200 
Hz : 
More than 
60 kohm 
 
6.4.2  off-hook AC impedance 
 
Required result:  400 ~ 1,400 ohm 
 
6.4.3  Return Loss 
 
Required result: More than 10 dB through frequency range 200 ~ 3,200 Hz 
 
 
 
6.5
 CALL ALERTING CHARACTERISTICS 
 
6.5.1  Minimum Ring Start Voltage 
 
Required result: 20 ~ 40 Vrms at 20 Hz (typical 27 Vrms) 
 
6.5.2  Ring sound level 
 
Required result: (at distance 50 cm for ring signal 20 Hz 70 Vrms) 
 
 
 
Maximum level  : 
more than 70 dBspl.
 
 
6.5.3  Message Waiting Indicator 
 
Required result: Minimum level 70 Vdc for MWI operation. 
 
 
6.6 RELIABILITY TEST 
 
6.6.1  Temperature test 
 
Required result: 
 
 
 
No operation error occurs during each condition; 
 
 
 
 
1) Setup chamber in 0
0
C for 12 hours 
 
 
 
 
2) Setup chamber in 40
0
C at R.H. 85% for 12 hours