Bakers Pride Dante Series XXE Manuale Utente

Pagina di 12
3
2. ACCEPTABLE CLEARANCES:
(A)
USA and Canada.
Due to intense heat generated by radiation, in USA and Canada these broilers should be installed in non-
combustible locations only, including the areas above the grate level.
MINIMUM CLEARANCE FROM NON-COMBUSTIBLE CONSTRUCTION:
Right Side 
Left Side 
Back 
50mm(2")
50mm (2")
50mm (2")
(B)
European Community Countries
Minimum clearance from:
           Right Side         Left Side
   Back
   Floor
Combustible construction
250mm
250mm
 250mm
150mm
 Non-combustible construction
 
 
50mm
 
 50mm 
 
 
50mm
100mm
3. GAS CONNECTION:
The  gas  pressure  regulator  supplied  must  be  installed  at  the  gas  inlet  of  each  broiler  unless  required 
otherwise by local codes. Each regulator is adjusted to yield a manifold pressure of 3.5" water column (9 
mbar) for natural gas or 10" water column (25 m bar) for propane gas. Units for propane gas are available 
for use in USA and Canada only.
Recommended minimum gas supply lines are listed below:
All XXE Models
3/4" 
(19 mm )
NOTE: A shut off valve in a readily accessible location must be installed on the gas supply line before 
connecting it to the unit.
For  units  using  propane  gas  supply  In  USA  and  Canada  lines  less  than'  1/2"  (12.7  mm)  Inside 
diameter should not be used.
On the XXE series, the gas connection is located on the right rear of the unit.
BE SURE TO CAP WHICHEVER SIDE IS NOT CONNECTED.
When making gas pipe connections, pipe joint compound resistant to the action of liquefied petroleum 
gases should be used.
The broiler and its individual shutoff valve must be disconnected from the gas supply piping system during 
any pressure testing of that system at test pressure in excess of 1/2 psig (3.45 kpa).
The broiler must be isolated from the gas supply piping system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig 
(3.45 kpa).
4. BURNERS
Check to see that air mixer caps on the front of all burners are adjusted and tightened, allowing half the 
opening to show.
To install the burners:
(A) 
Place the front venturi end of the burner into the valve assembly by fitting the center hole of 
the air mixer cap over the brass orifice.
(B) 
Drop the two ends of the burners over the burner support pins in the front and back of the 
chamber.