High End Systems High End LCD Controller for Studio Color Manuale Utente

Pagina di 272
6-20  
Remote Preset Access
Studio Color LCD Controller
audio 1 and 2 advance (page 6-27), color modulate (page 
6-27)
 and dim modulate (page 6-27) as needed.  These 
settings are stored with the preset. 
9.
Press the 
<Record>
 key.  The Select LED stops flashing, 
indicating the preset is now recorded.
Note
If enabling analog controller channels does not call up 
presets in memory, make sure there are no submasters 
assigned.  See the section titled “Submasters” on page 
6-23.
Playing Back in Twelve-Level Preset Access
1.
Enable the analog controller channel corresponding to the 
preset level you wish to access.  For example, to access one 
of the first level of eight presets, enable analog controller 
channel 1.  To access one of the second level of eight presets 
(9 through 16), enable controller channel 2.
Note
The highest-numbered channel takes precedence if 
you simultaneously enable two channels.
0V = Disabled
5V-10V = Enabled
2.
Toggle the 
<Address>/<Preset>
 key on the Studio Color LCD 
controller until the Preset LED is ON.
3.
Press one of the eight Preset keys on the Studio Color LCD 
controller’s front panel to play back that preset.
4.
The preset continues to play back until you: 
press another Preset key
change to another preset level by activating another 
channel on the controller
press  the 
<Standby>
 key until the Standby LED comes 
ON 
manually change the memory or page