7-20
IBM-Compatible
Studio Color LCD Controller
Verifying the Transfer
Make sure the memory was backed up properly using either 
Windows File Manager (or Explorer) or the DOS dir 
command.  The file should be about 256KB in size.  If so, 
you are finished.
If the file is smaller than 256KB, some problem occurred 
during the transfer.  Follow the troubleshooting suggestions 
below:
If the file was larger than 0KB but less than 256KB, the 
most likely cause was that something interrupted the 
transfer.  Check the cable connections on both ends, 
verify the cable or replace it with a known working cable.  
Begin again with the section titled “Initial Setup” on page 
7-15,
 making sure you do not press either the 
<ESC>
 key 
on your computer or the 
<Select>
 key on the controller 
until the transfer is complete.
If the file was 0KB, the most likely reason is you selected 
the wrong serial (COM) port.  You should also check the 
cable connections on both ends, verify the cable or 
replace it with a known working cable.  Begin again with 
the section titled “Initial Setup” on page 7-15, making 
sure you select the correct COM port.  
Restoring (Uploading) Memory from 
Computer to Controller
Before following this procedure, you must have already 
followed the instructions in the following sections: