High End Systems High End LCD Controller for Studio Color Manuale Utente

Pagina di 272
1-8
Setting the Controller Voltage
Studio Color LCD Controller
Set or Verify Controller Voltage
To change or verify the controller’s input voltage setting, 
locate the voltage selection switch on the rear panels shown in 
Figure 1-1 on page 1-9. 
115 volts – This setting should be used for power supplies 
rated from 90V to 127V.  Slide the switch so that “115” 
appears inside the switch opening.  You must also do both of 
the following:
Change the controller’s fuse as shown in the section titled 
“Replacing the Fuse” on page 1-9.
Verify the controller’s frequency by setting personality 
switch B-2 as shown in the section titled “Switch B-2: 
Time Base” on page 2-6
.
230 volts – This setting should be used for power supplies 
rated from 180V to 250V.  Slide the switch so that “230” 
appears inside the switch opening.  You must also do all of 
the following:
Change the controller’s fuse as shown in the section titled 
“Replacing the Fuse” on page 1-9.
Verify the controller’s frequency by setting personality 
switch B-2 as shown in the section titled “Switch B-2: 
Time Base” on page 2-6
.
Caution
Do not plug a controller set to 115 volts 
into a 230 voltage source.  Permanent 
damage will occur.