Install Range Hood
1. Using 2 or more people, hang range hood on 2 mounting 
screws through the mounting slots on back of hood.
2. Remove the grease filter. See “Range Hood Care” section.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws and tighten.
Connect Vent System
1. Install transition on top of hood (if removed for shipping) with 
2 - 3.5 x 6.5 mm sheet metal screws.
2. Fit vent system over transition piece.
3. Seal connection with clamps.
4. Check that back draft dampers work properly.
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install a UL 
listed or CSA approved
 ¹⁄₂" strain relief.
4. Run home power supply wiring through 
¹⁄₂" strain relief into 
terminal box.
5. Use UL listed wire connectors and connect white wires (B) 
together.
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
A. Vent transition
B. 3.5 x 6.5 mm screw
A
B
C
A
B
A. UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to 
yellow-green wires
E. Home power supply
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.