Electrical Requirements
There is no connection necessary beyond
plugging the unit into a polarized,
grounded, 120 volt, 60 Hz, 15 amp circuit.
The minimum of 102 VAC is required for
proper operation of gas ignition systems.
This circuit MUST be grounded and properly
polarized. The unit is equipped with a 16-
SPT2 power cord.
Gas Connection
This rangetop has a ¾” (1.9 cm) ID NPT
(Sch40) inlet connection. The gas supply
(service) line may be reduced, but not to less
than ½” (1.3 cm) ID NPT. Sealant on all pipe
joints must be resistive to LP gas.
The rangetop is designed specifically for
natural gas or liquid propane (LP) gas.
Before beginning installation, verify that
the model is compatible with the
intended gas supply.
Manual shut-off valve:
This installer-supplied valve must be
installed in the gas service line before the
appliance in the gas stream and in a location
where it can be reached quickly in the event
of an emergency. Any opening behind the
rangetop should be sealed.
In Massachusetts:
A “T” handle type
manual valve must be installed in the gas
supply line to the appliance.
IMPORTANT: Any conversion required
must be performed by your dealer or a
qualified licensed plumber or gas service
company. Please provide the service person
with this manual before work begins.
Pressure Regulator:
• All heavy-duty, commercial type cooking
equipment must have a pressure regulator
on the incoming service line for safe and
efficient operation, since service pressure
may fluctuate with local demand. External
regulators are not required on this
rangetop since a regulator is built into
each unit at the factory. Under no
condition bypass this built-in regulator.
• Manifold pressure should be checked with
a manometer, natural gas requires 5.0”
W.C.P. and LP gas requires 10.0” W.C.P.
Incoming line pressure upstream from the
regulator must be 1” W.C.P. higher than
the manifold pressure in order to check
the regulator. The regulator used on this
range can withstand a maximum input
pressure of 1/2” PSI (14.0” W.C.P.). If the
line pressure is in excess of that amount, a
step down regulator will be required.
• The appliance must be disconnected from
the gas supply piping system during any
pressure testing of that system.
ELECTRICAL SHOCK
HAZARD
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned off at the
breaker box and gas supply is turned off
until the rangetop is installed and ready
to operate, installation by an authorized
installer only.
Flexible Connections:
If the unit is to be installed with flexible
couplings and/or quick-disconnect fittings,
the installer must use a heavy-duty AGA
design-certified flexible connector of at least
1/2” (1.3 cm) ID NPT (with suitable strain
reliefs) in compliance with ANSI Z21.41
and Z21.69.
In Canada:
CAN 1-6, 10-88 metal
connectors for gas appliances and CAN 
1-6.9 M79 quick disconnect devices for use
with gas fuel.
In Massachusetts:
This appliance must be
installed with a 36” (3-foot) long flexible
gas connector.
Electrical & Gas Requirements 
Electrical & Gas Requirements