Viking TVWH480GB Istruzione Sull'Installazione

Pagina di 40
8
24"
(61.0 cm)
A
18"
(45.7 cm)
12"
(30.5 cm)
6"
(15.2 cm)
30" W 
29-7/8" (76.2 cm)
36" W 
35-7/8" (91.1 cm)
42" W 
41-7/8" (106.4 cm)
48" W 
47-7/8" (121.6 cm)
60" W 
59-7/8" (152.1 cm)
(VWH/CVWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VWH/CVWH 18”H. Wall Hoods
Description
30”
36”
42”
48”
60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
2
2
3
4
Number of filters
2
2
2
3
4
Heat lamps
1
1
1
2
3
Interior ventilator kits
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200
DIL1200
DIL1200
DIL1200
DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (24.5 cm)
Interior—Maximum amps
4.2/5.2/8.2
4.2/5.2/8.2
5.2/8.2
10.8
10.8
Exterior—Maximum amps
8.0/5.3
8.0/5.3
8.0/5.3
7.8/8.5
7.8/8.5
In-Line—Maximum amps
5.3/7.2
5.3/7.2
5.3/7.2
9.6
10.0
Dimensions & Specifications