Basic Specifications
Dimensions
5
D
De
essccrriip
pttiio
on
n
V
VG
GW
WT
TO
O5
52
24
41
1
Overall Width
24 3/4” (62.9 cm)
Overall Depth from Rear
To end of side panel -  28 5/8” (72.7 cm)
To endo of control panel  - 31” (78.7 cm)
To end of knobs - 32 3/4” (83.2 cm)
Overall Height
To cooking surface 11 3/4” (29.8 cm)
Cutout Width
26 1/4 ” (66.7 cm)
Cutout Depth
Minimum -  27 3/8” (69.5 cm)
Maximum - 27 7/8” (70.8 cm)
Cutout Height
10-1/4” (26.0 cm)
Gas Requirements
Natural: 
standard residential 1/2” (1.3 cm) ID gas service line.
LP/Propane:
standard residential 1/2” (1.3 cm) ID gas service line. or
equipped with high capacity hose/regulator assembly for connection
to standard 20 lb. LP/Propane gas cylinder with Type 1, QCC-1
connection.
U
Un
niitt  m
mu
usstt  b
be
e  o
orrd
de
erre
ed
d  N
Na
attu
urra
all  o
orr  L
LP
P//P
Prro
op
pa
an
ne
e  --  N
No
ott  F
Fiie
elld
d  C
Co
on
nvve
errttiib
blle
e
12 V - (8 AA batteries)
Electrical Requirements
Burner Rating
27,500 BTU Nat./27,500 BTU LP
(8.1 kW Nat./8.1 kW LP) 
Approximate Shipping Wt.
160 lbs. (72.0 kg)
26-1/4”
(66.7 cm)
28-5/8”
(72.7 cm)
32-3/4”
(83.2 cm)
Built-in Installation
1.  A minimum of 6” (15.2 cm) from the sides must be maintained from the unit above the cooking surface to adjacent vertical
combustible construction.  The unit is not to be located under overhead unprotected combustible construction.
2.  The side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop
3.  When determining a suitable location for the unit, take into account concerns such as exposure to wind, proximity to traffic
paths and keeping gas supply lines as short as possible.  Locate only in a well-ventilated area.  Never locate in a building,
garage, breezeway, shed or other such enclosed areas.
4.  In a built-in construction where an LP/Propane tank is going to be used, there MUST be some type of support (braces, cut-
out, etc.) to prevent tank from moving within the installation. The support must also allow the LP/Propane tank to withstand
a horizontal tipping force equal to the weight of the tank without tipping over. The tank can not tip over or deflect more
than 1.00 inch when a 38 lb. horizontal force is applied to a 20 lb. LP/Propane tank.
IIM
MP
PO
OR
RT
TA
AN
NT
T::    G
Ga
ass  ffiittttiin
ng
gss,,  rre
eg
gu
ulla
atto
orr,,  a
an
nd
d  iin
nsstta
alllle
err  ssu
up
pp
plliie
ed
d  ssh
hu
utt--o
offff  vva
allvve
e  m
mu
usstt  b
be
e  e
ea
assiillyy  a
acccce
essssiib
blle
e..
10-1/4”
(26.0 c
m)
36”
(91.4 cm)
27-3/8”
(69.5 cm)
24-3/4”
(62.9 cm)
*S
olid 
bot
to
suppor
t
Countertop typically 
requires 1/2” wide by 1/2” 
deep notch cutout on each 
side of grill. This allows grill 
Control Panel to sit back 
properly in the cutout.
6” min
(15.2 cm
)
Gas inlet 
location area
5”
(12.7 cm)
5”
(12.7 cm)
1/2”
(1.2 
cm
)
1/2”
(1.
2 c
m)