Do not clean the cooktop while it is still hot.  
Some cleaners produce noxious fumes when 
applied to a hot surface. 
 
CAUTION 
DO not allow aluminium foil, plastic, paper or cloth to 
come in contact with hot burners or grates. Do not 
allow pans to boil dry. 
 
 WARNING 
The California Safe Drinking Water and Toxic 
Enforcement Act requires the Governor of 
California to publish a list of substances known to 
the State of California to cause cancer, birth 
defects, or other reproductive harm, and requires 
businesses to warn of potential exposure to such 
substances. 
 
This product contains a chemical known to the 
State of California to cause cancer, birth defects, 
or other reproductive harm.  
This appliance can cause low-level exposure to 
some of the substances listed, including benzene, 
formaldehyde, carbon monoxide, toluene, and 
soot. 
 
Warnings for Gas and Electric Installation 
 
In case of Propane gas installation 
The cooktop is ready for use with natural gas. It may 
be converted for use with propane gas using the 
propane conversion kit supplied with the cooktop. 
Be sure the unit being installed is correct for the type 
of gas being used.  
Refer to the rating plate located on the underside 
burner box (see installation instruction). 
 
 WARNING 
Installation and service must be performed by a 
qualified installer, service agency or the gas 
supplier. 
 
 
CAUTION 

Always disconnect the electrical plug from the wall 
receptacle before servicing this unit. 

For personal safety, this appliance must be 
properly grounded. 

Do not under any circumstances cut or remove 
the third (ground) prong from the power cord plug. 
 
CAUTION 
When connecting the unit to propane gas, make 
certain the propane tank is equipped with its own high 
pressure regulator.  
In addition, the pressure regulator supplied with the 
cooktop must be on the inlet gas pipe of this unit. 
 
In case of electrical failure 
If for any reason a gas control knob is turned ON and 
there is no electric power to operate the electronic 
igniter of the cook top, turn OFF all gas control knobs 
and wait 5 minutes for the gas to dissipate before 
lighting the burner manually. 
To light the burner manually, carefully hold a lighted 
match to the burner ports and push and turn the gas 
control knob to HI until it lights and then turn the knob 
to desired setting.