Viking VMOS201WH Istruzione Sull'Installazione

Pagina di 20
E3
Cabinet or Wall Cutout
Provide an opening in the wall or cabinet as indicated 
in figure 
1
. The depth should be a minimum of 20-1/8" 
(51.1 cm). If the Depth (C) dimension is greater than 21" 
(53.3 cm), the outlet location may be in any area on the 
rear wall.  The floor of the opening should be constructed 
of plywood strong enough to support the weight of the 
oven (about 100 lbs.) and should be level for proper 
operation of the oven. 
Note: while the proper functioning of the oven does not 
require that the opening be enclosed (with sides, ceiling 
and rear partition), this may be required by local code, 
and it is suggested that the local code be checked for 
any such requirement. 
A
B
D
E
C
1
Surface Mount Cutout Dimensions
* For flush mount dimensions please see installation template and 
FLuSh MOuNT INSTALLATION on page 5-6.
CONVECTION
CONVENTIONAL
(A) Height
18-1/2"
(46.9 cm) Min.
16-3/4"
(42.5 cm)
Max.
17"
(43.2 cm)
(B) width
25"
(63.5 cm) Min.
24-3/8"
(61.9 cm)
Max.
24-11/16"
(62.7 cm)
(C) Depth
Min.
20-1/8"
(51.1 cm)
Min.
20-1/8"
(51.1 cm)
(D)
Min.
Max.
6"
11-1/2"
(15.2 cm)
(29.2 cm)
(E)
Min.
Max.
4"
5"
(10.2 cm)
(12.7 cm)
ELECTRICAL OuTLET LOCATION: Outlet should NOT be in the 
shaded area as indicated on figure 1. At the rear of the opening, 
provide a 3-pronged, polarized, electrical outlet, 115-120 volt AC, 
15 amp or larger.
2
DUCT (C)
DUCT (B)
SCREw (A)
EXhAuST DuCT ASSEMBLY: Insert the edge of DUCT (B) into the 
hold lip of DUCT (C). Secure together by using a SCREw (A) provided 
in the kit. See figure 2.
3
SCREw (A)
DUCT (A)-1
DUCT (BC)
SCREw (A)
EXhAuST DuCT ASSEMBLY: Position DUCT (A)-1 on the top of the 
oven inserting edge of DUCT (BC) assembly into hole lip of DUCT 
(A)-1. Tighten two SCREwS (A), securing DUCT (A)-1 to DUCT (BC) 
assembly. See figure 3.
4
SCREw (A)
SCREw (A)
DUCT (A)-2
DUCT (A)-1
EXhAuST DuCT ASSEMBLY: Position DUCT (A)-2 on the top of the 
oven and insert it into the hold lip of DUCT (A)-1. Secure DUCT (A)-2 
to DUCT (A)-1 using two SCREwS (A) provided. See figure 4.
5
SCREw (A)
SCREw (A)
SCREw 
(A)
DUCT (A)-3
DUCT (A)-2
EXhAuST DuCT ASSEMBLY: Position DUCT (A)-3 on top of the oven 
and insert it into DUCT (A)-2. Secure DUCT (A)-3 using three screws 
(A) provided. See figure 5.
Exhaust Duct Assembly