Ice maker
 
Fault
Possible cause
Remedial action
The ice maker doesn’t work.
Ice maker is not connected to the mains 
supply.
Call customer service.
Ice maker does not contain any fresh 
water.
Ensure that the water is properly connected. 
The freezer compartment temperature is 
too warm.
Check freezer compartment temperature and, 
if required, set slightly colder.
The ice maker does not make 
enough ice or the ice is 
deformed.
The appliance or ice maker has only just 
been switched on.
Approx. 24 hours is needed until ice production 
starts.
A lot of ice has been taken.
Approx. 24 hours is needed until the ice cube 
container is filled again.
Low water pressure.
Connect the appliance to the stipulated water 
pressure only (see chapter Connecting appli-
ance, section Water connection).
The water filter is bunged up or used.
Change the water filter.
Temperature in the freezer compartment 
is too warm.
Set temperature slightly colder in the freezer 
compartment.
Ice cubes have accumulated on the rear 
panel of the ice cube container.
Distribute ice cubes in the ice cube container. If 
ice cubes are stuck to each other, loosen with 
a blunt implement.
The ice maker does not make any 
ice.
The ice maker is switched off.
Switch the ice maker on at the control panel.
The appliance is not supplied with water. Contact the installer or the water supply com-
pany.
Water supply has kinks.
Turn off the water supply at the shut-off tap. 
Smoothen out the kinks, exchange where nec-
essary.
Low water pressure.
Connect the appliance to the stipulated water 
pressure only (see chapter Connecting appli-
ance, section Water connection).
Temperature in the freezer space is too 
warm.
Set temperature slightly colder in the freezer 
compartment.
Ice cube container is not properly 
inserted.
Check the position, re-insert where necessary.
Incorrect shut-off tap installed.
Incorrect taps can cause low water pressure 
and damage to the appliance.
Ice forms in the inflow hose 
to the ice maker.
Low water pressure.
Connect the appliance to the stipulated water 
pressure only (see chapter Connecting appli-
ance, section Water connection).
Shut off tap incorrectly opened.
Open shut off tap fully.
Water runs from the appliance.
The water connection hose is not prop-
erly sealed.
Replace the hose with a manufacturer’s origi-
nal part.
Incorrect shut-off tap installed.
Incorrect taps can cause low water pressure 
and damage to the appliance.