Connecting the appliance
Have a technician install and connect the appliance 
according to the enclosed installation instructions.
Do not remove the transportation protection devices 
from the shelves and storage compartments until 
the appliance has been installed.
Always connect the water before the power.
Apart from statutory national regulations, you should 
stick to the connection terms relating to the local 
electricity and water companies.
After installing the appliance, wait at least 1 hour until 
the appliance starts up. During transportation the oil 
in the compressor may have flowed into 
the refrigeration system.
Before switching on the appliance for the first time, 
clean the interior of the appliance (see chapter 
“Cleaning the appliance”).
Water connection
,
CAUTION: 
Connect the appliance to a drinking water line.
The water may be connected only by a competent fitter 
according to the local regulations of the appropriate 
water supply company.
A cold water connection is necessary for operating 
the automatic ice maker. The water pressure must be 
between 29 and 116 p.s.i. (2.0 and 8.0 bar). 
The installation must correspond to the local 
plumbing regulations.
A separate shut-off valve should be installed in 
the cold-water inflow.
The shut-off valve should not be located behind 
the appliance. It is recommended that you mount 
the shut-off valve directly next to the appliance or at 
another place which is easily accessible.
When installing the water connection, pay attention 
to the permissible installation area for the water 
mains.
For connection to the drinking water mains use only 
water pipes which are suitable for drinking water. 
Observe national regulations and the connection 
conditions of the local water supply companies.
Electrical connection
,
WARNING: 
Avoid the risk of an electric shock!
,
WARNING: 
Insert into a grounded 3-phase socket. Never remove 
grounding phase. Do not use any adapters. Do not use 
any extension cables.
,
WARNING: 
Non-compliance with these instructions may result 
in death, fire or an electric shock. Improper 
connection of the protective conductor may result in 
an electric shock. If you are in doubt whether 
the appliance has been grounded properly, have 
the appliance tested by a qualified electrician or 
service technician.
Do not use extension cables or distributors. This 
appliance must be connected to a permanently 
installed socket.
The socket must be near the appliance and also freely 
accessible following installation of the appliance.
The appliance complies with protection class I. 
Connect the appliance to 115 V/60 Hz alternating 
current via a correctly installed socket with protective 
conductor. The socket must be fused with a 10 to 16 A 
fuse.
The appliance comes with a UL registered 3-wire 
power cord. The appliance requires a 3-pole socket.
Please observe the following table with regard to this:
Check on the rating plate whether the indicated 
voltage and current type correspond with the values of 
your power supply. The location of the rating plate 
can be found in the chapter entitled Customer 
service.
,
WARNING: 
Never connect the appliance to electronic energy 
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters 
are used for photovoltaic systems which 
are connected directly to the national grid. Sine-
controlled inverters must be used for isolated 
applications (e.g. on ships or in mountain lodges) 
which are not connected directly to the national grid.
Appliance
Maximum simultaneous load
Fridge-freezer
6.0 amps