Instructions for the installer 
 
10
 
 
3.5  Clearance above and around domestic cookers 
Extract from AS5601 
 
 
REQUIREMENTS 
 
1
  Overhead clearances – (Measurement A
Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s 
instructions. However, in no case shall the clearance between the highest part of the 
hob  of the 
cooking 
appliance and a range hood be less than 600  mm or, for an overhead exhaust fan, 750 
mm
 
Any other downward facing 
combustible surface less than 600 mm above the highest part of the 
hob shall be protected for the full width and depth of the cooking surface area in accordance with 
Clause 5.12.1.2. However, in no case shall this clearance to any surface be less than 450 mm
 
2
  Side clearances – (Measurements B & C
Where B, measured from the periphery of the nearest 
burner to any vertical combustible surface, is 
less than 200 mm, the surface shall be protected in accordance with Clause 5.12.1.2 to a height C 
of not less than 150 mm above the 
hob for the full dimension (width or depth) of the cooking surface 
area. Where the cooking 
appliance is fitted with a ‘splashback’, protection of the rear wall is not 
required. 
 
3
  Additional requirements for Freestanding and Elevated Cooking Appliaces – (Measurements D & E
Where D, the distance from the periphery of the nearest 
burner to a horizontal combustible surface 
is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be above the 
trivet. See insets above. 
 
NOTES 
 
1
  Requirement 3 does not apply to a freestanding or elevated cooking appliance which is 
designed to prevent flames or the cooking vessels from extending beyond the periphery of 
the appliance. 
2
  The ‘cooking surface area’ is defined as that part of the appliance where cooking normally 
takes place and does not include those parts of the appliance containing control knobs. 
3
  For definition of hob, see Clause 1.4.64. 
4
  For definition of trivet, see Clause 1.4.109. 
5
  Consideration is to be given to window treatments when located near cooking appliances. 
See Clause 5.3.4.