Foster FHG 2L Manuale Utente

Pagina di 20
2
Introduction
The display case are manufactured in two formats FHG 2L, 2 doors, and the FHG 3L, three doors.
There are also Multiplex options that are a combination of two FHG 2L cases to make a FHG 4L or a combination
of the FHG 2L and FHG 3L to make a FHG 5L.
  
Technical Specification.
Model
2 Door
3 Door
4 Door
5 Door
External Dimensions (m)
Height (m)
2100
2100
2100
2100
Width (m)
1684
2463
3254
4035
Depth (m)
900
900
900
900
Internal Dimensions (m)
Height (m)
1354
1354
1354
1354
Width (m)
1564
2343
3128
3907
Depth (m)
550
550
550
550
No. of Shelves
12
18
24
30
Shelf capacity (each)
Kg
40
40
40
40
Door System
Schott
Schott
Schott
Schott
Refrigeration System
Compressor
Up to Aug
2004
Hitachi 
FL200 DL
400v 3 phase
Hitachi FL200
DL
400v 3 phase
(x 2)
From Aug
2004
Hitachi 
DS 183651
230v 1 phase
Hitachi 
DS 183651
230v 1 phase
(x 2)
Hitachi 
FL300DL
400 3 Phase
Hitachi 
FL300DL
400 3 Phase
(x 2)
Refrigerant
R404A 
2500 grms
R404A
3500 grms
R404A 
2500 grms 
(x 2)
R404A
2500 grms +
3500 grms
Vaporisation
Hot Gas
Hot Gas
Hot Gas
Hot Gas
Defrost Type
Hot Gas and 
Electric (1 kW)
Hot Gas and 
Electric 
( 1.5 kW)
Hot Gas and 
Electric
(2.1kW)
Hot Gas and 
Electric
(2.5 kW)
Electrical supply
230/1/50
400/3/50
230/1/50 X 2
400/3/50 +
230/50/1
Electrical Supply Capacity
16A
16A
16A
16A
Controller
Carel
PB00F0HB10
Carel
PB00F0HB10
Carel
PB00F0HB10
Carel
PB00F0HB10
Heat loads & Consumption
Lighting
Watts
140
210
280
350
Door frame heaters
Watts
266
380
522
646
Fan motors
Watts
132
198
264
330
Compressor consumption
Watts
2760
Compressor Duty
Watts
2660
Compressor Current
A
5.1