NCT Group NCT 2000T Manuale Utente

Pagina di 144
3.4
 OFFSETS Screens
40
For detailed description of work offset measure see the chapter 
7.2.2
 “Tool Length Offset
Measure inside the Machine” on the page 
79
.
3.4.5 RELATIVE POSITION OFFSETS Screen
In the general displaying area
below the current tool position
are the values of relative position
offsets. An inverse bar can be
moved on axis addresses by
means of keys 
 and 
.
This bar enables to select the
offset register to be modified.
Modification of registers does
not have the slightest effect on
program execution, this display
is only for the operator.
Actions of RELATIVE POSITION OFFSETS Screen
The following action menu can be activated to the RELATIVE POSITION OFFSETS screen
by means of action menu key 
:
Clear all
1
2
3
4
5
6
7
8
9
0
Clear All Action Menu: When pressing the key the question CLEAR ALL OFFSETS?
appear in the bottom left part of general displaying area, together with Exec and
Cancel actions in menu bar, the meaning of which is the usual.