  Upgrading Firmware and Managing Configuration Data
8.2.3 Loading Configuration Data via TFTP Client
Before the configuration can be loaded onto other F3400/F1000s, it must be checked for 
accuracy. Blank spaces or unwanted characters, such as the “Press <enter> to download the 
file” text, may be saved into the beginning of the configuration file. Open the file in Notepad 
and examine the first few lines. Delete any characters that were accidentally embedded into the 
file.
1
Verify that your PC is connected to the F3400/F1000 over the LAN and that port 69 is open 
between your PC and the Falcon.
2
Open your TFTP client. Configure the client as follows. 
a
Host = F3400/F1000 IP Address
b
Port = 69
c
Block Size = 64, 128, 256, 512, or 1024
Note
The file must be sent in BINARY (not ASCII).
3
The file name of the configuration being loaded must contain the .cfg extension.
4
Send or PUT the file. After a few seconds, the TFTP software should indicate when it is 
complete. 
5
Configurations are now loaded onto the replacement F3400/F1000. View the Falcon 
webpages to verify that the configurations are as expected.
8.2.4 Loading Configuration Data via EIA232 COM1 Port 
(X-Modem)
Before the configuration can be loaded onto other F3400/F1000s, it must be checked for 
accuracy. Blank spaces or unwanted characters, such as the “Press <enter> to download the 
file” text, may be saved into the beginning of the configuration file. Open the file in notepad 
and examine the first few lines. Delete any characters that were accidentally embedded into the 
file.
1
To load settings, go to the F3400/F1000 onto which the configuration will be loaded. Log 
into the F3400/F1000 (COM1) through HyperTerminal (Terminal Emulation Program). 
Navigate to the Load/Save Configuration Data Menu under the Main Configuration 
Menu. 
2
Select option 2 (
Load Xmodem 1K
) from the Load/Save Configuration Menu and press 
ENTER. Then select Transfer/Send File from the menu at the top of the HyperTerminal 
screen. 
3
Select the 1K X-Modem protocol. Locate the correct configuration file under Filename 
(Browse), select Open, and then select the Send button. 
4
Wait until the Upload is completed and enter X to exit the Load/Save Configuration Menu.