YOU WILL NEED TO SUPPLY:
TOOLS REQUIRED:
ŘComposite or Impervious shims/spacers  
(12 to 20)
ŘHigh quality exterior grade polyurethane or 
silicone sealant (3 to 4 tubes per door)
ŘGreat Stuff™ Window and Door Insulating 
Foam Sealant by the Dow Chemical Company 
or equivalent low pressure polyurethane 
window and door foam - DO NOT use high 
pressure or latex foams.
ŘWood blocking, 3/4" x 4" x 96" (2 or 3 pieces)
ŘScrews (#10 x 3-1/2")
ŘPella® SmartFlash™ foil backed butyl flashing 
tape or equivalent. 
ŘSill pan
ŘTape measure
ŘLevel
ŘSealant gun
ŘSquare
ŘHammer
ŘScrewdriver
ŘUtility knife
ŘWide jaw pliers
ŘReciprocating saw
Ř1/8" and 1/4" drill bit
ŘDrill
4&"-"/5
4&"-"/5
Installation will require two or 
more persons for safety reasons.
1A
A.  Remove the vent panel from the existing door frame. Check the dimensions of the 
existing door and the new door to make sure the new door will fit correctly. The opening 
must be 1/2" larger than the new door frame in both width and height. Measurements 
should be taken as follows:  
Width - measure the inside dimension of existing jambs.  
Height - measure from the subfloor or cement slab to the lowest point of the existing head. 
Confirm the flange will overlap the stucco by 1/2".
1
 
BEFORE YOU START