American Dryer Corp. ADS-464 Manuale Utente

Pagina di 81
40
S
AFETY 
D
EVICES
L
OCATION
F
UNCTION
C
OMPUTER
D
ISPLAY 
M
ESSAGE
R
ESULT  OF
T
RIPPING
L
OAD 
D
OOR 
S
WITCH
L
EFT 
S
IDE 
O
L
OAD
D
OOR
I
NSURES  DRYER  LOAD
DOOR  ARE  CLOSED
"DOOR
 
OPEN"
D
RYER  WILL  NOT  RUN
U
NLOAD  DOOR
SWITCH 
(T
WO  DOOR
UNIT  ONLY
)
R
IGHT  SIDE  OF
UNLOAD  DOOR
I
NSURES  DRYER
UNLOAD  DOORS  ARE
CLOSED
"DOOR
 
OPEN"
D
RYER  WILL  NOT  RUN
T
ILTING 
S
WITCHES
T
OP  LEFT  SIDE  OF
BASE  MODULE
I
NSURES  DRYER  IS
LEVEL
"LEVEL
 
FAULT"
D
RYER  WILL  NOT  RUN
D
RUM 
R
OTATION
S
ENSOR
L
EFT  SIDE  OF
TUMBLER  SECTION
I
NSURES  TUMBLER  IS
ROTATING
"DRUM
 
FAULT"
S
TOPS  HEAT  ONLY
L
INT 
C
HAMBER  AIR
PRESSURE  SWITCH
C
ENTER  OF  HEAT
C ONSOLE
I
NSURES  PROPER  AIR
FLOW  THROUGH  DRYER
"AIRFLOW
FAULT"
S
TOPS  HEAT  ONLY
B
URNER 
F
AN 
A
IR
F
LOW 
S
WITCH 
(G
AS
D
RYERS 
O
NLY
)
C
ENTER  OF  HEAT
C ONSOLE
I
NSURES  PROPER
CAOMBUSTION  AIR
FLOW  INTO  THE
BURNER  BOX
"HEATER
 
FAULT"
S
TOPS  HEAT  ONLY
H
I
/L
G
AS 
P
RESSURE
S
WITCH 
(G
AS 
D
RYERS
O
NLY
)
L
OWER  LEFT  OF  HEAT
CONSOLE  SECTION
I
NSURES  PROPER  GAS
SUPPLY  PRESSURE  FOR
ADEQUATE  IGNITION
"GAS
 
SUPPLY
FAULT"
S
TOPS  HEAT  ONLY
H
EAT 
R
ECLAIMER
D
AMPER 
S
WITCH
R
IGHT  SIDE  OF  HEAT
C ONSOLE
I
NSURES  THAT  THE
HEAT  RECLAIMER  IS
EITHER  OPENED  OR
CLOSED
I
NPUT 
LED
 
#13
  OF
THE 
PLC
  IS  OFF
N
ONE
H
EAT 
C
ONSOLE 
D
OOR
A
CC ESS 
D
OOR
S
WITCH
I
NSIDE 
H
EAT
C
ONSOLE
I
NSURES  THAT  ACCESS
DOORS  ARE  CLOSED
"DOOR
 
OPEN"
D
RYER  WILL  NOT  RUN
E
XHAUST 
A
IR 
T
EMP
C
ONTROL 
S
ENSOR
I
NSIDE 
B
URNER
SECTION  DUCT
M
ONITORS  TUMBLER
EXHAUST  AIR  TEMP
"EXHAUST
 
DSFL"
S
TOPS  HEAT  ONLY
E
XHAUST 
A
IR 
H
I
T
EMP 
C
ONTROL
S
ENSOR
I
NSIDE  EXHAUST  DUCT
M
ONITORS  TUMBLER
EXHAUST  AND  AIR  TEMP
"HI-TEMP
 
FAULT"
S
TOPS  HEAT  ONLY
I
NTAKE 
A
IR 
T
EMP
C
ONTROL 
S
ENSOR
(
OPTIONAL
)
T
OP  RIGHT  OF
TUMBLER  SECTION
M
ONITORS  TUMBLER
AIR  INTAKE  TEMP
"INTAKE
 
DSFL"
S
TOPS  HEAT  ONLY
I
NTAKE 
A
IR 
T
EMP
C
ONTROL 
S
ENSOR
T
OP  RIGHT  OF
TUMBLER  SECTION
M
ONITORS  TUMBLER
AIR  INTAKE  TEMP
"HI-TEMP
 
FAULT"
S
TOPS  HEAT  ONLY
B
URNER 
H
I
-L
IMIT
S
AFETY 
S
ENSOR
T
OP  OF  BURNER
SECTION
M
ONITORS  AIR  TEMP
ABOVE  THE  BURNER
BOX
"HI-TEMP
 
FAULT"
S
TOPS  HEAT  ONLY
S
PRINKLER 
C
ONTROL
S
AFETY 
S
ENSOR
T
OP  RIGHT  OF
TUMBLER  SECTION
O
PEN  SPRINKLER
SYSTEM  WATER  VALVE
ON  HI
-
TEMP  CONDITION
O
RANGE  SPRINKLER
PILOT  LIGHT  COMES
ON
.
   
A
LARM  HORN
SOUNDS
O
PENS  THE  SPRINKLER
WATER  VALVE  AND
POWER  DOWN  THE
WHOLE  DRYER
L
INT 
D
RAWER
S
WITCHES
A
BOVE  LINT  DRAWER
HANDLES
D
ISABLES  MACHINE
WHEN  DRAWERS  ARE
OPEN  OR  IF  DRAWERS
HAVE  NOT  BEEN
CLEANED  IN  LAST  FIVE
LOADS
.
L
INT 
D
RAWER
D
RYER  WILL  NOT  RUN