Agilent Technologies FS2334 Manuale Utente

Pagina di 59
 
30
Export 
This function takes the data captured and exports it in .csv format to a location the user 
selects. 
Repetitive Run 
This function allows the user to set-up the tool to trigger the logic analyzer a predefined 
number of times and capture data incrementally on each run. Please note this function 
does not work in Off Line mode. 
 
Timing Analysis 
 
This window tab provides an analysis of each Data bit’s window during every data burst 
across an entire TimingZoom trace. The user can set a threshold criteria in this window 
and then select whether the data windows to be identified should be equal to, greater 
than or equal to, or less than or equal to that value. All Data bits during any burst 
captured in a TZ trace will be listed in the Timing Analysis window. 
 
Additionally, the tool provides some overall statistics on what was measured in the TZ 
trace that was analyzed. This includes the number of Read and Write strobes analyzed, 
the % of data strobes with data transitions occurring; as well as, the maximum, minimum 
and average Data Bit widths across ALL bits during ALL bursts in the TZ trace. 
 
Export 
This function takes the data captured and exports it in .csv format to a location the user 
selects.