Toshiba IP5000-UG-VC Manuale Utente

Pagina di 208
IP5122-SDC
IP5122-SDC Programming
98
Strata CIX IP5000-series Telephone UG     07/09
IPT Initialization
The IP5122-SDC has a fourth initialization option (FB4). ACO Default.
1. Press 
3
+
6
+
9
+
Hold
 (simultaneously).
2. Press 
Vol
 
s then press Hold.
3. Press 
FB04
. Revert to factory default ACO settings or Use the saved ACO 
settings. (LED On = revert to factory default, LED OFF = use the saved ACO 
settings). This will set all the IP5122-SDC program options to factory default 
values.
IP5122-SDC Headset Transmit Level Adjustment
The IP5122-SDC headset transmit level for ACO and IPT operation are set by 
programming from the station.
1. Press 
3
+
6
+
9
+
Hold
 (simultaneously).
2. Press 
#
 then press Hold.
3. Set the headset transmit level using FB1, FB2 and FB3 as shown in the table 
below.
4. Press Hold again.
Headset Transmit Levels
Transmit Level
FB1
FB2
FB3
IPT Level
ACO Level
Max. (louder)
OFF
OFF
OFF
+12 dB4
+8 dB
ON
OFF
OFF
+8 dB
+8 dB
OFF
ON
OFF
+4 dB
+4 dB
(Default)
ON
ON
OFF
0 dB
0 dB
OFF
OFF
ON
-4 dB
-4 dB
ON
OFF
ON
-8 dB
-7 dB
OFF
ON
ON
-12 dB
-7 dB
Min. (softer)
ON
ON
ON
-16 dB
-7 dB