Honeywell VRX180 Manuale Utente

Pagina di 294
Setpoint Profiler 
 
Video Recorder – User Manual 
 
203
How to hold a profiler 
Table 5-14   Profiler Hold Procedure 
Step 
Action 
Result/Notes 
Perform steps 1 and 2 from Start procedure 
(Table 5-13). 
Profile menu is displayed. 
Press Decrement button to move cursor to 
Hold. Press Enter. 
The profiler is held at its present value and the 
segment’s events are frozen.  Elapsed time 
continues.  Run time stops.  Events are held at 
their current states. 
 
ATTENTION 
A profile can also be put on HOLD by pressing the F2 button, but only if that profile’s HOLD parameter was 
configured as SY1 F2.  See Section 5.4. 
 
 
How to reset a profiler 
Table 5-15   Profiler Reset Procedure 
Step 
Action 
Result/Notes 
Place profiler in Hold. 
See Profiler Hold procedure inTable 5-14. 
Perform steps 1 and 2 from Start procedure 
(Table 5-13). 
Profile menu is displayed. 
Press Decrement button to move cursor to 
Reset.  Press Enter. 
Profiler is reset to segment #1.  All profiler timers 
are reset.  All events go OFF.  Profiler output 
goes to starting value of segment #1. 
 
ATTENTION 
A profile can also be RESET by pressing the F3 button, but only if that profile’s RESET/RUN parameter was 