Honeywell VRX180 Manuale Utente
Online Operations Using Primary Displays
Video Recorder – User Manual
214
Interacting with Panel_4 Display
To stop the rotation of the panel display on a precise point series, follow the procedure in Table 6-3.
H
14 JAN 99
21:35
DEWP IM
177,6
DEG C
AIR OUT
212,3
DEG F
PRESSURE
55,2
PSI
SY1
OFF
Figure 6-4 Panel Display
Table 6-3 Stop Panel_4 Display Rotation Procedure
Step
Action
Result
1
Press Tab key
Displays menu item SET HOLD at the lower right hand corner of the
display.
display.
2
Press Tab key
Displays the desired point series.
3
Press Enter
Holds display on desired point series. An “H” appears in the lower right of
the display.
the display.
To resume rotation through all points, follow the procedure in Table 6-4.
Table 6-4 Resume Panel_4 Display Rotation Procedure
Step
Action
Result
1
Press Tab key
Displays menu item REL HOLD at the lower right hand corner of the
display.
display.
2
Press Enter
The “H” disappears and rotation resumes.