AVE DR8X Manuale Utente

Pagina di 46
User’s Manual 
 
   
 
40 
 
To configure dome protocol, select a camera first and set the communications 
protocol associated with dome camera using the Direction keys and ENTER. 
The available protocol includes <DynaColor>, <Pelco D>, <Pelco P>, 
<AD422>, <Fastrax 2> and <None> (default).   
 
NOTE: The settings become effective after saving the changes and 
exiting from the menu. 
 
4.6.3  
RS485 Setup 
AVE DR16X / AVE DR8X series controls the domes via RS-485 
communication protocol. The RS-485 parameters of AVE DR16X / AVE DR8X 
series must be set to the same as the parameters set in dome camera . 
 
Users are allowed to change the RS-485 settings of the AVE DR16X / AVE 
DR8X
 series. Select <System Setup> in Main menu, then select <RS485 
Setup> from the System Setup menu and press ENTER. The following menu 
is displayed. 
 
RS485 Setup 
1 Unit ID                                       
2 Baud Rate                 
3 Bits 
4 Stop 
5 Parity    
224   
9600 

None 
 
The ID number must match the ID address set by the dome. The Unit ID is in 
the range of 1 to 255. The default ID is 224. Note that no two devices on the 
same bus should be given the same ID address, or a conflict may occur. 
 
The default AVE DR16X / AVE DR8X series RS-485 settings are 9600 Baud, 
8 Data Bits, 1 Stop Bit and No Parity. 
 
NOTE: The settings become effective after saving the changes and 
exiting from the menu.