Toshiba DK424 Manuale Utente

Pagina di 424
System & Station
Program 15 – Ground/Loop/Tie/DID Line Options
Strata DK Programming     5/00
3-47
System & Station
Program 15 – Ground/Loop/Tie/DID Line Options
Processor Type:
DK14, DK40i, all RCTUs and BCUs
Program Type:
System
Initialized Default:
All LEDs are Off
✱  ✱  ✱ ✱  6SNU   +ROG  6SNU
+ROG  6SNU   +ROG  6SNU   +ROG
Processor Type
CO Line Range
Processor Type
CO Line Range
DK14
001~004
B1CU
001~032
DK40i
001~012
B2CAU/BU
001~120
RCTUA
001~016
B3CAU/BU
001~120
RCTUBA/BB
001~048
B5CAU/BU
001~200
RCTUC/D
001~144
RCTUE/F
001~200
Pro
g
ra
m Co
de
Program
LED On
LED Off
Line
LED
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
0
CPC on AR VM 
Calls and Voice 
Calls
Detect Ignore
1
CO/DID/Tie Line 
Signal
DP
DTMF
2
CO/DID/Tie Dial 
Pulse Rate
(Pulse per sec.)
20 PPS
10 PPS
3
AR Hold
Detect 
Ignore
4
AR Timing
Crossbar 
95 msec.
ESS 
(electronic) 
450 msec.
5
Tandem CO Line 
Connection with 
Station Dropout
Enabled
Not 
Enabled
7
Forced Account 
Code
Enabled
Not 
Enabled
8
Operation After CO 
Line Flash
No DTMF 
receiver 
After Flash
DTMF 
receiver 
After Flash
SELECT = Program Code
Press 
6FUROO
 to advance or 
3DJH
 to go 
back.
To advance the CO line range, press 
6FUROO
 
located beneath the LCD. Press 
3DJH
 for a 
lower range.
LED Buttons = CO line
Specify CO line by setting LEDs as defined by the 
table below. When you are finished, all LEDs with 
an “X” should be lit.