Scheda Tecnica (108025 102515)SommarioCOBRITHERM(1DESCRIPTION1Insulated Metal Substrate (IMS), based on thick aluminium and clad with ED copper foil in the other side. It is designed for a reliable thermal dissipation circuitry. With a proprietary formulated reinforced-polymer-ceramic bonding layer with a high thermal conductivity, dielectric strength, and thermal endurance is guaranteed.1The material is supplied with a protective film on the aluminium side to protect it against wet PCB process1ROHS compliance directive 2002/95/EC1STANDARD CONSTRUCTIONS1Aluminium thickness11000 - 1500 - 2000 - 3000 (m1Aluminium Alloy / Treat15052 H181Insulation thickness1110 - 130 (m1Dielectric thickness tolerance1+ 10 (m1ED copper thickness135 - 70 - 105 - 210 (m1Other constructions available upon request1PROPERTIES11500 (m Al / 130 (m dielectric /70 (m Cu1TEST1METHOD1UNITS1TYPICAL VALUES1Guaranteed values1Time to blister at 288ºC, floating on solder (50 x 50 mm)1IEC-611891Sec1>1201>1201Copper Peel strength, after heat shock 20 sec/288ºC1IPC-TM 650-2.4.81N/mm12,81>1,81Dielectric breakdown voltage, AC (1)1IPC-TM 650-2.5.6.31kV18171Proof Test, DC (2)1--1V13000130001Thermal conductivity (dielectric layer)1ASTM-D 54701w/m.ºK11,4511,451Thermal impedance (dielectric layer) x 10-31ASTM-D 54701ºK.m2/w10,08910,0891Surface resistance after damp heat and recovery1IEC-611891MΩ110511051Volume resistivity after damp heat and recovery1IEC-611891MΩm110411041Relative permitivity after damp heat and recovery, 10 kHz1IEC-611891-14,514,51Dissipation factor after damp heat and recovery 10 kHz1IEC-611891-10,0210,021Comparative tracking index (CTI)1IEC-611121V160016001Capacitance1--1pF/cm²1461461Flammability, according UL-94, class1UL-941class1V-01V-01Glass transition temperature of dielectric layer ( by TMA)1IPC-TM 650-2.4.241ºC1901901Maximum operating temperature1--1° C1150115011(1) Dielectric Breakdown test, is a material destructive laboratory test. It is performed according the IPC-TM-650 part 2.5.6.3., under AC voltage, raising it until electric failure, on relative small surface area of the dielectric part, and using metal electrodes. Values should be taken as a material reference, and not as guaranteed values.1(2) Electrical proof test. 100% of our laminate production delivered, has been “on line” verified at 3000 Vdc: 500 V/sec. ramp // 5sec. held at 2000 Vdc.11AVAILABILITY1STANDARD SHEET SIZES mm.1610 x 440, 920 x 610, 1060 x 5851Tolerance1+5/-0 mm.1Squareness13 mm max., as differential between diagonal measurements.1Standard size tolerance in panels1+- 0,3 mm.11The data is based on typical values of standard production and should be considered as general information. Our company reserves the right to future changes. It is the responsibility of the user to ensure that the product complies with his requirements.111AISMALIBAR, S.A.1Ctra. de Ripollet, 1, 08110 Montcada i Reixac (BCN) SPAIN1Tel. +34 93 565 63 00 Fax. +34 93 565 63 271Dimensioni: 173 KBPagine: 1Language: EnglishApri il manuale