19  BUILT-IN I/O FUNCTION
19.1  High-speed Counter Function
Special relay details
Details concerning special relays used for high-speed counters are explained below.
High-speed counter operating
Device for monitoring operation status of each channel of the high-speed counter.
Corresponding devices
The device numbers corresponding to each channel are as follows.
Operation Description
The content of the operation when ON and when OFF is as follows.
These devices also operate when the FX3 compatible high-speed counter function is valid.
Update timing
The timing of device update is as follows.
High-speed counter pulse density/rotational speed being measured
Device for monitoring operation of the high-speed counter when using pulse density/rotational speed measurement mode.
Corresponding devices
The device numbers corresponding to each channel are as follows.
Operation Description
The content of the operation when ON and when OFF is as follows.
If the FX3 compatible high-speed counter function is valid, these devices operate only when the SPD 
instruction operates.
Update timing
The timing of device update is as follows.
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
SM4500
SM4501
SM4502
SM4503
SM4504
SM4505
SM4506
SM4507
Operation when ON
Operation when OFF
High-speed counter operating
High-speed counter stopped
ON
OFF
• High-speed counter driven by the HIOEN instruction
• SPD instruction ON execution
• UDCNTF instruction is executed ON (when the FX3 compatible high-speed 
counter function is valid)
• High-speed counter stopped by the HIOEN instruction
• Power ON, reset, STOP, PAUSE
• UDCNTF instruction is executed OFF (when the FX3 compatible high-
speed counter function is valid)
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
SM4516
SM4517
SM4518
SM4519
SM4520
SM4521
SM4522
SM4523
Operation when ON
Operation when OFF
Pulse density/rotational speed measurement mode operating
Updates measurement results by measuring unit time.
Pulse density/rotational speed measurement mode stopped or not being used
ON
OFF
• Pulse density/rotational speed measurement mode is set in parameter and 
pulse density/rotational speed measurement is driven by the HIOEN 
instruction.
• SPD instruction ON execution
• Pulse density/rotational speed measurement mode is set in parameter and 
pulse density/rotational speed measurement is stopped by the HIOEN 
instruction.
• Power ON, reset, STOP, PAUSE