Mitsubishi Electronics FX5 ユーザーズマニュアル

ページ / 306
11  REMOTE OPERATION
11.4  Relationship Between Remote Operation and CPU Module
91
11
11.4
Relationship Between Remote Operation and CPU 
Module
Relationship between remote operation and RUN/STOP status of the CPU module
The following table shows operation status of the CPU module by the combination of remote operation and RUN/STOP status 
of the CPU module.
*1 When executing by the RUN contact, setting of RUN contact is required in the CPU parameter.
*2 Remote reset setting is required in the CPU parameter.
*3 When a CPU module is changed to STOP status by a remote operation, remote reset is possible.
*4 Includes even the cases where CPU module has stopped due to an error.
Switch RUN/STOP status
Remote operation
RUN
STOP
PAUSE
RESET
RUN
RUN
STOP
PAUSE
Operation not possible
STOP
STOP
STOP
STOP
RESET