Mitsubishi Electronics FX-10P.E ユーザーズマニュアル

ページ / 126
ix
3.2
Expansion of Device Range
• For a list of the new device ranges see section 2.
Handling index registers
“V0” and “Z0” index registers are equivalent to registers “V” and “Z” respectively, so either one
can be used for programming.
When entering “V1” to “V7” or “Z1”  to “Z7” add a numeral 1 to 7 to the “V” or “Z” before
pressing 
 or 
 .
3.3
Parameter setting
When a RUN terminal is needed on the PC, select “USE”, and specify an input number from
X000 to X017 (X000 to X007 only for FX
2N
-16M
✰ and FX
2NC
-16M
✰).
Number of file register blocks
0 to 14 blocks can be specified for file registers. These occupy program space, 1 block = 500
program steps, and are stored with the program. File registers start at D1000.
SP
GO
MEMORY SETTING
   2K  4K  8K  16K
Addition of 16K steps
   RUN  INPUT
   USE         X002
Setting of external RUN input
   DON'T  USE