Mitsubishi Electronics 0 ユーザーズマニュアル

ページ / 136
25
CHAPTER 3 SPECIFICATIONS
3
3.
3 F
unct
ion List
3.3
Function List
The following table lists the functions of the high-speed counter module.
● These functions can be used together. 
However, select either the linear counter function or the ring counter function and any one of the counter functions from 
counter function selection.
● The preset function and the function selected from counter function selection can also be performed by the following 
external inputs.
• To use the preset function, apply a voltage to the preset input terminal.
• To use any function of the counter function selection, apply a voltage to the function start input terminal.
Item
Description
Reference
Linear counter function
This function counts pulses between -2147483648 and 2147483647 and detects an 
overflow if the count value is outside the range.
Ring counter function
This function repeatedly counts pulses between the ring counter upper limit value 
and the ring counter lower limit value.
Coincidence 
output function
This function compares the present counter value with the preset coincidence output 
point setting value and outputs on or off signal when they match.
Coincidence 
detection 
interrupt 
function
This function outputs an interrupt signal to the CPU module and starts an interrupt 
program when the present counter value matches with the preset coincidence output 
point setting value.
Preset function
This function overwrites the present counter value with the preset value.
This function is performed by a program or an external control signal (preset input).
Counter function 
selection
Count disable 
function
This function stops counting pulses while CH Count enable command (Y4, YC) is 
on.
Latch counter 
function
This function stores the present counter value to the buffer memory when the 
counter function selection start command signal is input.
This function is performed by a program or an external control signal (function input).
Sampling 
counter function
This function counts pulses input during the specified sampling period after the 
counter function selection start command is input and stores the counter value to the 
buffer memory.
This function is performed by a program or an external control signal (function input).
Periodic pulse 
counter function
This function stores the present and previous counter values to the corresponding 
buffer memory areas at the preset cycle while the counter function selection start 
command signal is input.