Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
6 - 100 
6. APPLICATION FUNCTIONS 
 
6.29.4 Operation example 
(1) When the pass position interrupt is complete 
The pass position interrupt (PPIOP) turns on between the operation start and the completion of all pass 
position interrupt outputs. When the pass position condition is satisfied, the factor of interrupt of the "pass 
position interrupt complete  " ( : pass position condition number) turns on and the interrupts are output. 
The pass position interrupt (PPIOP) turns off and the pass position interrupt complete (PPIFIN) turns on 
when all of pass position interrupts are output. 
Passing
Pass position condition 1
Pass position condition 2
Passing
Pass position interrupt complete 1
Pass position interrupt complete 2
During operation
(OP)
ON
OFF
Pass position
condition start number
1
Running pass
position condition number
0
             1
2
Pass position
condition end number
2
Pass position
interrupt
(PPIOP)
ON
OFF
ON
OFF
ON
OFF
Pass position
interrupt complete
(PPIFIN)
Pass position
interrupt incomplete
(PPIERR)