Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
6 - 143 
6. APPLICATION FUNCTIONS 
 
6.31.7 Combinations of continuous operation to torque control and other functions 
The following shows the combinations of continuous operation to torque control with each function. 
 
Classification Function Compatibility
Remarks 
System 
function 
SSCNET 
communication 
method 
SSCNET /H 
 
 
SSCNET  
 
 
Control mode 
Standard mode 
 
 
Interface mode 
 
 
Operation 
function 
JOG operation 
— 
 
Incremental feed 
— 
 
Automatic operation 
 
Automatic switch/Manual switch can be selected.
Linear interpolation 
 Linear 
interpolation 
. When starting up a 
continuous operation to torque control point, 
"continuous operation to torque control error 
(operation alarm 5D, detail No.0A)" occurs. 
Home position return 
— 
 
Home position reset function 
— 
 
Application 
function 
Command unit  Electronic gear 
 
 
Speed unit 
Speed unit 
 
Set the continuous operation to torque control 
speed limit value in speed units. 
Speed units multiplication factor 
 
 
Speed limit 
 
The continuous operation to torque control speed 
limit value is restricted by speed limit value 
(control parameter No.0222, No.0223) 
Acceleration/ 
deceleration 
Linear acceleration/deceleration 
 
 
Smoothing filter 
 
Invalid during continuous operation to torque 
control. 
Start up speed validity 
 
Valid when starting up operation point. However, it 
is invalid during continuous operation to torque 
control. 
S-curve acceleration/deceleration 
(Sine acceleration/deceleration) 
 
Invalid during continuous operation to torque 
control. 
Servo off 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Forced stop 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Stop operation 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Rapid stop operation 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Limit switch (stroke end) 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Software limit 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Interlock 
 
Control mode is automatically changed to position 
control mode after an operation alarm occurrence.
Rough match output 
 
At continuous operation to torque control points 
the rough match turns ON when the distance 
remaining based on the position data of the point 
table is within the rough match output range. 
Torque limit 
 
During continuous operation to torque control and 
torque limit, torque limit stays OFF. 
: Usable       : Unusable       : Restriction      —: Not applicable