7. AUXILIARY FUNCTION 
 
7.11 Reconnect/disconnect function 
7.11.1 Disconnection function summary 
By turning on the disconnection command, SSCNET communication with selected axis and later can be 
disconnected. 
To use this function, set the consistency check selection at system startup of the control cycle (parameter 
No.0002) to invalid. This function becomes available after the system is started.  
The axes whose communication is disconnected become non-communicating axes, so their power supplies 
can be turned off and SSCNET cables can be detached. At this time, communicating axes are not affected. 
 
Note. If the power supplies of communicating axes are turned off or their SSCNET  cables are detached, a system error of the position 
board occurs and the axes enter forced stop status. 
 
POINT 
 
Refer to the controlling axis information after the disconnection is completed 
to check the bit corresponding to the non-communicating axis is off. 
 
API LIBRARY  
Use the sscDisconnectSSCNET function to disconnect SSCNET 
communication. 
 
 
Communicating axes
Axis 1
Axis 15
Axis 14
Axis 16
Communicating axes
Axis 16
Axis 14
Axis 15
Axis 1
Non-communicating axes
Can be turned off and detached.
DI
SSCNET
DI
SSCNET
USB
USB
Set 000Dh to the
disconnecting axis (axis 14)
and turn on the
disconnection command.