Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
7 - 40 
7. AUXILIARY FUNCTION 
 
7.12.2 Command/status bit 
System command/status bits related to sampling function are shown below. 
System command 
 
System status 
Address Bit  Symbol 
Signal 
name 
 
Address
Bit Symbol 
Signal 
name 
03E1 0  SMPS 
Sampling 
start 
 
0451
SMPW 
Waiting for sampling trigger 
1  
Reserved 
 
SMPO 
Sampling is being performed 
 
2 SMPF 
Sampling 
is 
complete 
 
3 SMPE 
Sampling 
error 
 
4  
Reserved 
 
 
 
 
Address Bit  Symbol 
Signal 
name 
 
Address
Bit Symbol 
Signal 
name 
03F2 
0 SMPSW 
Sampling setting write 
command 
 
0462
0 SWFIN 
Sampling setting write 
complete 
 
Reserved 
 
1 SWEN 
Sampling setting number error
 
2 SWED 
Sampling setting data out of 
bounds 
 
3  
Reserved 
4 SMPSR 
Sampling setting read 
command 
 
4 SRFIN 
Sampling setting read 
complete 
 
Reserved 
 
5 SREN 
Sampling setting number error
 
 
Reserved 
 
 
(1) Details concerning system command bits 
 
Symbol Signal 
name 
Function 
details 
SMPS Sampling 
start 
[Function] 
Starts sampling. 
[Operation] 
When the sampling start signal (SMPS) is turned on, storage of sampling data is started. 
SMPSR Sampling 
setting 
 
read command 
[Function] 
Reads sampling setting. 
[Operation] 
Reads sampling setting set to sampling setting read number. When the sampling setting read 
number is incorrect, sampling setting read will not be performed. 
(Remarks) The sampling setting read command is valid only while system is running. 
SMPSW Sampling 
setting 
 
write command 
[Function] 
Writes sampling setting. 
[Operation] 
Writes sampling setting set to sampling setting write number. When the sampling setting 
write number is incorrect and the sampling setting to be written is outside the setting range, 
the sampling setting write will not be performed. 
(Remarks) The sampling setting write command is valid only while system is running.