Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
7 - 47 
7. AUXILIARY FUNCTION 
 
7.12.5 Details for sampling function settings 
Settings related to sampling function are shown below. Each setting is imported when the sampling is started 
(SMPS: ON). The sampling setting cannot be changed while Waiting for sampling trigger (SMPW) is on and 
Sampling is being performed (SMPO) is on. 
 
(1) Sampling setting 
 
Setting No. 
Name 
Initial value Setting range
Remarks 
0001 Sampling 
option 
00000000h 00000000h 
to 
000029FFh
Sampling cycle
Set the sampling cycle.
00h to FFh: Control cycle
   (setting +1)
[Example]
If the sampling cycle is set to 3 with
the control cycle set to 0.44ms,
sampling is executed every
1.777ms.
0 0
Trigger mode
Set the trigger mode.
0: Trigger turns on when the
sampling is started.
1: Trigger turns on when one
    of each trigger condition is
    satisfied.
2: Trigger turns on when all of
    the trigger conditions are
    satisfied.
0 0
Pre-trigger
Set the timing that the trigger
condition is satisfied.
0 to 9: Setting    10%
[Example]
When pre-trigger is 10% with
8192 points of sampling
points, 819 points of data
0002 
Sampling points 
8192 
0 to 65536
Set the points to be sampled. 
0003 
For manufacturer setting 
00000000h
 
 
0004 00000000h
0005 00000000h
0006 00000000h
0007 00000000h
0008 00000000h
0009 00000000h
000A 00000000h
000B 00000000h
000C 00000000h
000D 00000000h
000E 00000000h
000F 00000000h