Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
9 - 2 
9. INTERFACE MODE 
 
9.2 Combinations with functions 
The following shows the combinations of interface mode with each function. 
 
Classification Function 
Control mode 
Remarks 
Position
control
Speed 
control
Torque
control
Operational 
function 
JOG operation 
 
 
 
 
Incremental feed 
 
 
 
 
Automatic operation 
 
 
 
 
Linear interpolation 
 
 
 
 
Home position return 
 
 
 
The normal home position return function is 
invalid. After moving to the home position, use 
the home position set command. 
Check the DOG signal status with the high-
speed monitor. 
Home position reset function 
 
 
 
 
Application 
function 
Command units  Electronic gear 
 
 
 
Command units are always pulse units. 
Speed unit 
Speed unit 
 
 
 
Related only to speed units during monitor 
output. 
Speed units multiplication 
factor 
 
 
 
Related only to speed units during monitor 
output. 
Speed limit 
 
 
 
 
Acceleration/ 
deceleration 
Linear 
acceleration/deceleration
 
 
 
 
Smoothing filter 
 
 
 
 
Start up speed validity 
 
 
 
 
S-curve acceleration/ 
deceleration (Sine 
acceleration/deceleration)
 
 
 
 
Servo off 
 
 
 
The system becomes servo free. Follow up 
processes are not performed after servo off. 
Perform them with the user program. 
Operation stop by servo off is invalid. Perform 
servo off after a deceleration stop. 
Forced stop 
 
 
 
 
Stop operation 
 
 
 
 
Rapid stop operation 
 
 
 
 
Limit switch (stroke end) 
 
 
 
Check the LSP/LSN signal status with the 
high-speed monitor. 
Software limit 
 
 
 
 
Interlock 
 
 
 
 
Rough match output 
 
 
 
 
Torque limit 
 
 
 
 
Command 
change 
Speed change 
 
 
 
 
Change of time constants
 
 
 
 
Position change 
 
 
 
 
Backlash 
 
 
 
 
Position switch 
 
 
 
 
Completion of operation signal 
 
 
 
 
Interference check function 
 
 
 
 
Home position search limit 
 
 
 
 
Gain switching 
 
 
 
 
: Usable       : Unusable       : Restriction