9. INTERFACE MODE 
 
9.5.2 Position control mode 
Position control mode is where position commands (absolute position in pulse units) generated by the user 
program can be sent to the servo amplifier. The position command buffer is made up of position data × a 
maximum of 64 ring buffers, and is controlled with the latest position command buffer number and the 
transmitting position buffer number. 
Refer to Section 9.5.5 or Section 9.5.6 for the update method of the buffer. 
 
POINT 
 
• For the setting value of the position command buffer, ensure that the 
difference between the previous command value and the current command 
value is no more than 20000000. When the difference between the previous 
command value and the current command value exceeds 20000000, 
command data error (operation alarm A7, detail No.03) occurs, followed by an 
immediate stop. 
• When an alarm other than command data error (operation alarm A7, detail 
No.03) occurs, conduct a deceleration stop by the user program.
 
 
 
In-position (INP)
Position command data
0
100 200 300
400 to 10000
10000
Position
10000
 
 
(1) Parameter 
(a) System parameter 
 
Parameter No.  Abbreviation 
Name 
Remarks 
000F 
*IFMO 
Interface mode option Specify the interrupt output cycle and command data update cycle.
 
(b) Control parameter 
 
Parameter No.  Abbreviation 
Name 
Remarks 
0210 TLP 
Forward 
rotation 
torque limit value 
Becomes valid when using torque limit. 
0211 TLN 
Reverse 
rotation 
torque limit value 
023F *IFBN 
Interface 
mode 
maximum buffer 
number 
Set the maximum buffer number of the position command buffer. 
Note. When interrupt output is invalid in interface mode, 1 or 
higher must be set.