Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
3 - 6 
3. INSTALLATION AND WIRING 
 
3.2.2 Forced stop input cable 
(1) Precautions for handling the forced stop input cable 
• For connection or removal of the forced stop input cable, do it surely while holding a connector of forced 
stop input cable. 
Position board
Tab
 
(2) Connection of the forced stop input cable 
• For connection of a forced stop input cable to the position board, connect it surely to an EMI connector of 
position board while holding a connector. Be sure to insert it until it clicks. 
 
(3) Removal of the forced stop input cable 
• For removal of the forced stop input cable, push a tab and pull out the cable while holding a connector. 
 
 
POINT 
 
The following handling will damage the position board or forced stop input 
cable. 
• Forced removal of the forced stop input cable from the position board. 
• The forced stop input cable is twined other cables. 
• Excessive power is applied at cable laying. 
Wire the cable correctly.