9. Attach angled end of long hose to fill valve at bottom of dryer 
back panel. Screw on coupling by hand until it is seated on fill 
valve connector. 
10. Using pliers, tighten the coupling an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
11. Check that the water faucets are on.
12. Check for leaks around “Y” connector, faucet, and hoses.
LEVEL DRYER
Check the levelness of the dryer. Check levelness first side to side, 
then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a 
wrench to adjust the legs up or down and check again for levelness.
COMPLETE INSTALLATION
1. Check that all parts are now installed. If there is an extra part, go 
back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials. 
4. Check the dryer’s final location. Be sure the vent is not crushed or 
kinked.
5. Check that the dryer is level. See “Level Dryer.”
6. Remove the blue protective film on the console and any tape 
remaining on the dryer.
7. Wipe the dryer drum interior thoroughly with a damp cloth to 
remove any dust.
8. Read “Dryer Use.”
Electric Models Only
9. For power supply cord installation, plug into a grounded outlet. 
Gas Models Only:
10. Check that gas supply is on.
11. Check for leaks.
Steam Models Only:
12. Be sure the water faucets are on.
13. Check for leaks around “Y” connector, faucet, and hoses.
14. If you live in a hard water area, use of a water softener is 
recommended to control the buildup of scale through the water 
system in the dryer. Over time, the buildup of lime scale may clog 
different parts of the water system, which will reduce product 
performance. Excessive scale buildup may lead to the need for 
certain part replacement or repair.
All Models:
15. Select a Timed Dry heated cycle, and start the dryer. Do not select 
the Air Only Temperature setting.
If the dryer will not start, check the following:
Controls are set in a running or “On” position.
Start button has been pushed firmly.
Dryer is plugged into an outlet and/or electrical supply 
 
is connected.
Household fuse is intact and tight, or circuit breaker has 
 
not tripped.
Dryer door is closed.
This dryer automatically runs an installation diagnostic routine at the 
start of its first cycle.
If you receive an L2 code, there may be a problem with your 
home power supply keeping the dryer’s heater from turning on. 
See “Troubleshooting.”
If you receive an AF code, your dryer vent may be crushed or 
blocked. 
See “Troubleshooting.”
NOTE: You may notice a odor when the dryer is first heated. This 
odor is common when the heating element is first used. The odor 
will go away.