Whirlpool W10164159B ユーザーズマニュアル

ページ / 56
12
When connecting to the terminal block, place the hooked end of the 
wire under the screw of the terminal block (hook facing right), 
squeeze hooked end together and tighten screw, as shown. 
1. Loosen or remove center, silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire) of 
direct wire cable under the center screw of terminal block (hook 
facing right). Squeeze hooked end together. Tighten screw. 
A
C
D
E
B
A. External ground conductor screw
B. Neutral ground wire
C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
3
/
4
" (19 mm) UL listed strain relief
3. Place the hooked ends of the other direct wire cable wires under 
the outer terminal block screws (hooks facing right). Squeeze 
hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to 
“Venting Requirements.”
Optional 3-wire connection 
Use for direct wire or power supply cord where local codes do 
not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center, silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and the neutral wire (white or 
center wire) of power supply cord/cable under center, silver-
colored terminal block screw. Tighten screw.
A
B
C
D
F
E
A. External ground conductor screw
B. Neutral ground wire 
C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
3
/
4
" (19 mm) UL listed strain relief
F. Grounding path determined by a qualified electrician
3. Connect the other wires to outer terminal block screws. Tighten 
screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external ground 
conductor screw to an adequate ground.