SEPARATION PRESSURE ADJUSTMENT
Adjust the separation pressure as follows:
WARNING
Wait at least 3 minutes after turning off the power before replacement.
ACHTUNG
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie mit dem
Austausch beginnen.
Austausch beginnen.
Roller ASY
Lever (green)
Power switch
Upper transport unit
Lever
1 Turn off the power switch.
Make sure that the hopper
table is at the bottom.
table is at the bottom.
2 Open the upper transport unit.
(See page 4-2)
3 Disconnect the two relay
connectors on the roller ASY.
4 Push the two levers (green)
towards each other to dis-
engage with the upper locking
holes and lower down the two
levers until they engage with
the two levers locking holes.
engage with the upper locking
holes and lower down the two
levers until they engage with
the two levers locking holes.