April 1999
Programming Procedures 
3-42
System Operator Positions 
3
System Operator Positions
3
A system operator position, for a Queued Call Console (QCC) operator or a 
Direct-Line Console (DLC) operator, should be programmed before you program 
lines or trunks.
Use the following procedures either to add an operator position or to change an 
existing operator position. 
The Queued Call Console (QCC) operator position is available only for Hybrid/
PBX systems. The Direct-Line Console (DLC) operator position is available in any 
mode and must be programmed if you have Call Management Systems 
connected to any operator extension jacks.
 shows the maximum number of operator positions allowed for any one 
system.
Table 3-1.
Maximum Number of Operator Positions
Any combination of operator positions can be assigned as long as no more than 
four operator positions are QCCs and the total number of operator positions does 
not exceed eight.
If you want to designate a new operator position and the system already has the 
maximum number of operator positions, you must change an existing operator 
position to a nonoperator position before you designate a new operator position.
Position Type
Type of Telephone
Maximum Positions
QCC
MLX-20L
4
DLC
MLX-20L 
MLX-28D
Analog multiline telephones
MERLIN II Display 
Consoles
8
Total QCC + DLC
8