Programming Procedures 
3-49
Lines and Trunks 
3
Lines and Trunks
3
The procedures in this section are used to assign optional features to individual 
lines and trunks. The following optional features can be assigned:
Type of Trunk
Outmode Signaling for Loop- or Ground-Start Trunks
Rotary Trunk Digit Transfer
Disconnect Signaling Reliability
Toll Type
Hold Disconnect Interval
Principal User for Personal Line
QCC Queue Priority
QCC Operator to Receive Calls
Incoming Call Line Identification Delay
Trunks to Pools Assignment
The Copy Options feature (described at the end of this section) allows you to copy 
several optional features from an idle trunk. This option eliminates the need to 
individually enter each feature.
Separate sections cover 
,” 
,”
,” and 
.”
A slot is the physical location of the individual module on the control unit. There is 
a maximum of 17 slots, which are numbered as follows:
Basic carrier: slots 1 through 5
First expansion carrier: slots 6 through 11
Second expansion carrier: slots 12 through 17
A port is a line or trunk jack on the module. Individual modules support different 
numbers of ports. On any module, port 1 is the lowest physical jack position. For 
modules with both line and extension jacks, the port numbers for the line jacks 
follow the numbers for the extension jacks instead of beginning with 1. For 
example, for a 408 LS-ID-MLS module, the port numbers for the extension jacks 
are 01 through 08 and the port numbers for the line jacks are 09 through 12.