Lucent Technologies 555-670-111 ユーザーズマニュアル

ページ / 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Programming Procedures 
3-261
BRI Facilities 
3
BRI Facilities
3
The procedures in this section provide the steps for programming the following 
options for Basic Rate Interface (BRI) facilities connected to an 800 NI-BRI 
module:
Service Profile Identifier (SPID) and Directory Number (DN)
Timers
NOTES:
The 800 NI-BRI module is only available in Release 4.0 and later.
If you are adding BRI facilities to an existing system, clock 
synchronization must be set correctly. To inspect or change these 
values, se
Service Profile Identifier (SPID) and
Directory Number (DN)
3
Use this procedure to program the Service Profile Identifier (SPID) and Directory 
Number (DN) for each BRI line in the system. Until these values are programmed 
for each line, the system considers the BRI line inactive and the line will not 
initialize.
NOTE:
The system will not be forced idle when SPIDs are entered. However, if for 
some reason a SPID changes, the line must be idle (no active call on the 
line) in order to change the SPID. 
Summary: Service Profile Identifier (SPID) and
Directory Number (DN)
3
Programmable by 
System Manager
Mode 
Key, Hybrid/PBX
Idle Condition 
Not required
Planning Form 
3i, Incoming Trunks: BRI Options (800 NI-BRI module)
Factory Setting 
none
Valid Entries 
SPID: up to 20 digits (any combination of 0 to 9)
DN: up to 10 digits (any combination of 0 to 9)
Inspect 
No
Copy Option 
No