Honeywell 2-Partitioned Security System ユーザーズマニュアル

ページ / 36
 
– 13 – 
5800 Series Transmitters Loop Designations 
LOOP
1
5 8 0 2 M N
ENROLL AS "UR" OR "RF"
YOU MUST
ENROLL THIS 
BUTTON
LOOP 3
LOOP 1
LOOP 2
LOOP 4
LOOP
1
5808
ENROLL AS "RF"
5 8 0 4
ENROLL 
AS "BR"
5 8 1 7
ENROLL AS "RF"
LOOP 1
(PRIMARY)
LOOP 2
(AUX. CENTER)
LOOP 3
(AUX. RIGHT)
LOOP 1
(MOTION)
5 8 9 0
ENROLL AS "RF"
5 8 1 6
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 1
(TERMINALS)
5 8 2 7
SET HOUSE CODE
5 8 2 7 B D
SET HOUSE CODE
5 8 1 6 M N
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 1
(TERMINALS)
5 8 1 9
ENROLL AS "RF"
LOOP
2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE 
POSITION
FOR LOOP 2
LOOP 3
(TERMINALS)
5 8 1 9 S   ( W H S   &   B R S )
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 1
(INTERNAL
SHOCK
SENSOR)
LOOP 3
(TERMINALS)
5 8 5 0   ( G B D )
ENROLL AS "RF"
(Green)
(Red)
(Yellow)
5 8 0 4 B D
ENROLL AS "BR"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
SET 
HOUSE 
CODE
YOU MUST
ENROLL THIS 
BUTTON
LOOP
1
5809
ENROLL AS "RF"
5 8 0 1
ENROLL AS "UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
••
••
• •
• •
•••
5800_trans_loop-V0
 
Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for 
details regarding loop numbers, etc. 
 
UL
 
The 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, 5827BD, 
and 5850 transmitters are not intended for use in UL installations. 
 
PROMPT 
EXPLANATION 
 
 
XMIT TO CONFIRM 
PRESS 
✱TO SKIP 
Confirmation Option: This prompt only appears if you answered “Yes” at the first prompt. The system 
enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate 
the loop input or button that corresponds to this zone. At any time during this step, you may press the [
✱] key 
on the keypad to save the serial and loop number combination without confirming.  
 
Entd 
A022-4063      1 
Rcvd 
A022-4064       
If the serial number transmitted does not match the serial number entered, a display similar to the one 
at the left appears.  If the loop number does not match, it is also displayed. 
If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary 
display does not appear), press the [#] key twice and then enter or transmit the correct serial number. 
 
10  ZT   P  RC   In   L 
03   1   3C   RF  1s 
If the serial number transmitted does match the serial number entered, the system beeps 3 times and a 
summary display appears, showing that zone’s programming.  Note that an “s” indicates that a transmitter’s 
serial number has been enrolled.  
Press [
✱] to accept the zone information.