Honeywell F500 ユーザーズマニュアル

ページ / 8
F500 WHOLE HOUSE/ LIGHT COMMERCIAL HEPA FILTRATION SYSTEM
3
68-0263-2
PLANNING THE INSTALLATION
Selecting Mounting Position and Location
The F500 can be suspended from exposed ceiling joists or the 
ceiling surface, or it can be floor-mounted. 
1.
Install the F500A in a conditioned space or the F500B in 
an unconditioned space using these guidelines.
2.
Plan the unit location to minimize duct lengths.
3.
Locate an existing electrical outlet with the appropriate 
current rating to plug in the power cord. (If an outlet is 
not available, have a qualified electrician install one.)
4.
Choose a location that is readily accessible for checking 
and replacing the filter. (Allow at least 26-1/2 in. (673 
mm) clearance in front of the unit.) 
Planning Ducting
The F500 can be mounted to the whole-house forced air 
system using a bypass configuration or can be independently 
ducted to stand alone. See Fig. 2, 3, and 4 for typical 
installations.
The Whole House/Light Commercial HEPA air cleaner has 
4 in. x 10 in. duct flanges to easily attach the external 
ductwork. 
The intake port can be moved to a more convenient 
location, if necessary: 
Simply cut a new 4 in. x 10 in. hole in the desired loca-
tion and block off the old hole. 
Reattach the duct flange over the new hole.
A transition can be used to connect round ducting to the 
Whole House/Light Commercial HEPA System. 
Keep duct sizes as large as possible throughout the 
installation (8 in. minimum diameter ducting is recom-
mended). 
Keep intake and exhaust duct runs as short as possi-
ble with few bends or elbows.
The F500 can be installed with a heat recovery ventilator. 
See Fig. 4.
Fig. 2. Typical F500 bypass installation.
Fig. 3. Typical F500 independent installation.
Table 1. Replacement Media Recommendations.
Filter (in in.)
Part Number
Replacement Interval
Normal
Light Duty
Carbon-Odor Filter (24 x 12)
32006026-001
3 months
4 months
Pleated Prefilter (24 x 12 x 2)
32006027-001
12 months
16 months
HEPA Filter (24 x 12)
32006028-001
3 years
5 years
S688A1007
SAIL SWITCH
(OPTIONAL)
HIGH EFFICIENCY
AIR CLEANER
120 VAC 60 HZ SUPPLY WITH GROUND
M20263A
RETURN AIR
F500
AIR
HANDLER
(FURNACE)
15 AMP LIGHT SWITCH
120 VAC 60 HZ SUPPLY WITH GROUND
M20579
F500