For large fires, the maximum heating benefit from the fireplace will be 
obtained with its glass doors fully open. The open doors will allow more 
radiant heat to be emitted out of the front opening of the fireplace. When 
the glass doors are open, close the fireplace’s mesh screens 
to help keep burning embers from popping out of the firebox. 
With a small fire, it is best to operate the fireplace with its glass doors 
fully closed to prevent excessive room air from being drawn up the 
chimney. To prevent room air from escaping up the chimney overnight, 
close the fireplace glass doors before retiring in the evenings.
With the provided AK6A combustion air kit installed on the 
fireplace, outside combustion air may enter the firebox through 
a dampered opening located on the left side of the fireplace. 
This feature reduces the room air used for combustion and 
prevents excessive heat loss from the room. When the fire-
place is in use, this damper should be open
. When the 
fireplace is not in use, the damper may be closed to prevent 
cold air from entering the firebox. The outside combustion 
air control lever is located inside the fireplace firebox just 
above the brick panel on the left side of the firebox as shown 
by Figure 5. 
NOTE: Outside combustion air damper is open when 
its control lever is up. The damper is closed 
when its control lever is down. 
The fireplace must be supplied with outside combustion air 
when the fireplace is installed in a manufactured home. See the 
Outside Combustible Air section of this manual for additional 
information about outside combustion air.
This fireplace is equipped with a factory-installed fan assem-
bly to help circulate heat produced by the fireplace. The fanʼs 
ON/OFF rocker switch is installed in the left side of the lower 
louver panel on the front of the fireplace. Use the ON/OFF 
rocker switch to turn the fan on and off as desired for heat 
circulation. See the Wiring for Fan Assembly, page 27 of this 
manual for additional information about fan assembly. 
Figure 3 - Correct Position 
Figure 4 - Incorrect Position
The  fireplace  should  be  operated  only  with 
its  glass  doors  fully  open  or  fully  closed.  If 
glass  doors  are  left  partially  open,  gas  and 
flame may be drawn out of fireplace opening. 
This creates risks of both fire and smoke. See 
Figures 3 and 4.
W
ARNING
Fireplace 
Fireplace 
 Glass Doors Fully Open
 Glass Doors Partially  
Open
Do not 
operate 
fireplace like 
this! 
HOW THIS FIREPLACE WORKS
Figure 5 - Outside Combustion Air Control Lever Location 
Air Combustion Control Lever