624WBPF Woodburning Fireplace
chiMNey caP iNStallatioN
1.  Extend the regular chimney sections until the top of the chimney is 4” below the total flue height 
desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is 
completed.
2.  Remove the shingles from around the chimney so that the flashing may be installed, with the upper 
part of the flashing under the shingles.
3.  Set the flashing on the roof.  Hold a section of the outside pipe (13” diameter) on the flashing and 
scribe  a  line  around  the  flashing,  then  cut  the  top  off  the  flashing  by  cutting  1/4  inch  below  the 
scribed line. This should increase the diameter of the flashing outlet sufficiently to allow the flashing 
to be placed over the chimney. Figure 19
4.  Snap the last section of inlet air duct in place and slide the flashing over the chimney. Adjust the 
chimney to assure that the proper minimum clearances are maintained.
5.  Nail the flashing securely in place with eight nails.
6.  Seal the crack between the top of the flashing and the chimney with mastic. Leave some excess 
mastic at this area to be used in step eight. Note:  Use pliers and wear gloves when performing 
step seven to minimize the danger of cutting your hands on the edge of the storm collar.
7.  Place the storm collar around the chimney and put the collar together like a belt in belt loops.  Slide 
the end of collar under the two loops on the other end with the loops facing up. Overlap the ends of 
the collar until it is tight against the chimney. Bend the free end of the collar back over the loops to 
hold the storm collar securely together. The excess end of the storm collar may be trimmed off.
8.  Slide the storm collar down snugly against the flashing until the excess mastic left in step six is 
forced up into the crack between the storm collar and the chimney. This should make the joint be-
tween the flashing and the chimney watertight.
9.  Install the chimney cap by placing the cap into matching parts of the last chimney section. Then 
punch or drill 1/8 inch diameter holes in the inlet air duct (chimney pipe) where specified on the 
brackets and fasten it down with the No. 8 screws provided. Do not penetrate the inner stainless 
steel pipe while installing the screws.
10.Check all the parts of the fireplace, chimney and chimney termination cap to assure that no parts 
have been damaged or bent during installation and that all parts have been installed properly. 
Note:  The metal used for the chimney cap has a rust protective coating but the cut edges of the parts 
are not protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chim-
ney and chimney cap should be detergent washed and painted with a galvanized primer paint.
156O” Min. 
Overlap 
2” Min. 
FP1899 
chimney cap 
8/08 
RLTCF11 Chimney Cap 
Design Incorporates Lon-
ger Duct and Flue Pipe for 
Chase Type Installation
Chase  Top  Flat  Flashing  Does 
Not  Require  Venting  or  Standoff 
Spacers Around Perimeter
Chase
Roof Line
Maintain  2”  Minimum  Air 
Space Clearance to Combus-
tibles Above Roof Line
Using Tabs Provided, Secure Outer 
Telescoping to the Flat Flashing
On Large Chase Tops it is Recommended that 
Cross Supports be used to Provide Additional 
Support to Eliminate Sagging of the Flashing
13” Max. Space Between Chimney 
Section and Chase Cover
Outer Telescope
Note: Locally built chase flashings must incorporate a 
13Z\₄ min. to 13³\₄ max. x 2” high min. flanged hole for proper 
installation of the RLTCF11 chimney cap.
Figure 20
FP1899