Regency Wraps P36-NG4 ユーザーズマニュアル

ページ / 44
Regency
®
 P36-4 Gas Log Fireplace
11
INSTALLATION
FLUEING
Regency
®
 Direct  Vent System (Flex)
Horizontal Terminations Only
These fl ueing systems, in combination with the P36 Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type fl ue system 
by the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in 
section "Exterior Flue Termination Locations."
Regency
®
 Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the P36 with a maximum run 
of 1200mm.
1)  175mm dia. fl exible liner (1200mm length)
2)  100mm dia. fl exible liner (1200mm length)
3) spring 
spacers 
(4)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1-1/2" Drill Point, Stainless
 Steel 
(4)
If longer runs are needed, the Regency
®
 Direct 
Vent system (Flex) # 946-516 includes all the 
parts needed to install the P36 with a maximum 
3.0m run.
1)  175mm dia. fl exible liner (3.0m length)
2)  100mm dia. fl exible liner (3.0m length)
3) spring 
spacers 
(7)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1-1/2" Drill Point, Stainless
 Steel 
(4)
Notes: 
1)  Liner sections should be continuous without any joints or seams.
2)  Only Flex pipe purchased from Regency
®
 may be used for Flex installations.
3)  If you are installing the P36 into a Regency
®
 Mantel Kit, use the minimum horizontal vent height (centre-line  of 1029mm). Remember 
to include the mantel base in your calculations and to maintain the 32mm clearance  (38mm with Flex) to the underside of the mantel 
top.
6-7/8"
(173mm)
dia. Flue pipe
4" (102mm)
dia. flue pipe
spring spacer
Termination Cap
(Part# 946-578/P)
AstroCap
(patented)
Wall Thimble